JH-IDEC9000
1/8
Industrial Air Cooler

JH-IDEC9000

Two-stage indirect-direct evaporative cooler, 9,000 m³/h airflow, 12.5TR (44kW) cooling capacity, 4.2kW total power, 14-16°C supply air, 200-250m² coverage

JH-IDEC9000 is a two-stage indirect-direct evaporative cooler for plants, data centers, warehouses, clean rooms. Indirect pre-cools without adding humidity; direct cools supply air to 14-16°C. 9,000 m³/h, 12.5TR (44kW), 4.2kW total.

Why Choose This Model

Product Highlights

01

Two-Stage Indirect-Direct Cooling

Indirect stage pre-cools intake air without adding moisture, then direct stage brings supply air to 14-16°C—10°C lower than single-stage evaporative coolers

02

120% Wet-Bulb Efficiency

Surpasses the 100% wet-bulb limit of standard evaporative coolers—pre-cooled intake air lets the direct stage deliver colder supply air than single-stage designs can achieve

03

85% Power Cut vs DX

4.2kW total power delivers 12.5TR (44kW) of cooling—replacing traditional DX systems that would draw 28kW+ for equivalent capacity

04

70% Less Humidity Increase

Indirect-first architecture means most cooling happens without adding moisture to supply air—ideal for dry-climate industrial spaces and electronics manufacturing

05

IP54 Industrial Enclosure

Dust-protected and splash-resistant electrical cabinet for harsh industrial environments—paired with a 0.72 power factor and 8.5A total current on 400V/3/50 power

Core Advantages

14-16°C Supply Air, Even at 45°C Ambient
Stable Cooling

14-16°C Supply Air, Even at 45°C Ambient

The two-stage IDEC architecture pre-cools intake air through a heat exchanger (zero moisture added), then the direct evaporative stage achieves final cooling. Supply air temperature stays steady at 14-16°C, with up to 18°C total temperature drop — approaching air-conditioner comfort without the compressor.

4.2kW Replaces 28kW+ DX Systems
85% Power Cut

4.2kW Replaces 28kW+ DX Systems

Centrifugal primary blower (2.6kW) plus secondary axial fan (0.85kW) deliver 44kW of cooling from just 4.2kW total input. Cuts electricity consumption by 80-85% versus equivalent packaged DX air conditioners. Precision thermostat control with inverter variable-speed drive keeps energy use exactly where needed. Carbon emissions reduced by up to 85%.

No Recirculation, No CO₂ Buildup
100% Fresh Air

No Recirculation, No CO₂ Buildup

Unlike conventional packaged AC systems that recirculate indoor air, the IDEC9000 draws 100% fresh outdoor air and exhausts directly to the outside. Continuous air replacement eliminates indoor CO₂ accumulation and stale air. Compressor-free construction removes the highest-cost failure point in traditional HVAC under high-temperature conditions.

IP54, Washable Filter, Automatic Drain
Low Maintenance

IP54, Washable Filter, Automatic Drain

IP54-rated electrical enclosure withstands dust and water spray. Reusable washable air filter and programmable automatic drain system keep routine maintenance to a minimum. Two independent water tanks (indirect 0.15m³ + direct 0.063m³) with DN15 inlet and DN25 drain. Precision thermostat control with inverter drive maximizes runtime efficiency.

Technical Specifications

Airflow

9000 m³/h

Power

4.2kW

Coverage

200-250m²

Dimension

2120×2320×1320mm

Model
JH-IDEC9000
Cooling Capacity
12.5TR / 44kW
Total Power
4.2kW
Total Current
8.5A
Voltage / Phase / Frequency
400V / 3 / 50
Power Factor
0.72
Water Pressure
0.3-0.6 MPa
Indirect Water Tank
0.15 m³
Direct Water Tank
0.063 m³
Water Consumption
40L/H
Primary Blower Type
Centrifugal
Primary Blower Power
2.6kW
Primary Blower Speed
1400/1270 rpm
Primary Blower Airflow
9000/7500 m³/h
Primary Blower Static Pressure
250Pa
Secondary Fan Type
Axial
Secondary Fan Power
0.85kW / 1.15HP
Secondary Fan Airflow
9000 m³/h per fan
Ingress Protection
IP54
Net Weight (Operating)
800kg
Dry Weight
550kg
Shipping Weight
570kg
Water Inlet
DN15
Water Drain
DN25